Albumin Corrected Anion Gap

The classic anion gap hides acidosis whenever albumin is low, because albumin carries most of the unmeasured negative charge in blood. Correcting adds two and a half milliequivalents for every gram per deciliter of albumin below four. This tool computes the plain gap and its albumin corrected version, the number critical care and nephrology teams actually trust in sick hypoalbuminemic patients.

🔒 Your data never leaves your browser — nothing is stored or sent anywhere.

📊

Your visual report appears here

Fill in the form and press Calculate. You will get your number, an interpretation chip, and a personalized chart pack drawn instantly in your browser.

  • Risk spectrum with your position marked
  • Reference ranges from the original publication
  • Shareable link, nothing stored
Scientific references

    Blood stays electrically neutral, so the routinely measured ions, sodium on the positive side, chloride and bicarbonate on the negative side, leave a remainder. That remainder, the anion gap, reflects unmeasured anions such as lactate, ketones, toxins and, in large part, albumin itself. A rising gap signals that acid is accumulating somewhere.

    The Albumin Problem

    Albumin supplies the largest share of those unmeasured anions in health. When illness, malnutrition or kidney loss drags albumin down, the measured gap falls mechanically, even while dangerous acids pile up. A septic patient with albumin of two can show a textbook normal gap of eight while carrying lactate that should have raised it to thirteen. Roughly a quarter of significant high gap acidoses get missed this way in intensive care data.

    The Correction Rule

    The standard fix adds two and a half milliequivalents per liter for every gram per deciliter that albumin sits below four. Some laboratories and studies prefer a factor nearer two point three or use a baseline of four point four, which shifts answers slightly, but the clinical message is unchanged, low albumin demands an upward adjustment before the gap is judged.

    Reading the Result

    A corrected gap under twelve is generally normal. Twelve to sixteen sits in a gray zone worth watching. Above sixteen demands a hunt for the acid, lactate from shock or sepsis, ketones from diabetes or starvation, renal failure products, or ingested toxins like methanol and salicylate.

    The gap is a screening instrument, not a verdict. Confirmatory testing with lactate, ketones and osmolal gap closes the case, and normal gaps never rule out mixed acid base disorders on their own.